- Home
- Equipment
- Pump modules
- Handlers
Handlers
It is intended for breaking up gas bubbles to obtain a quasi-homogeneous mixture and subsequent supply of a gas-liquid mixture to the ESP inlet.
Maximum allowable free gas content at the inlet: 55%
Principle of operation
: the impellers of the breakers grind the gas inclusions to a homogeneous suspension
Description of identifiers
The structure of the pump module identifier in orders, correspondence and in other documentation:
- no letter
- working rotation of the shaft is right (serial)
- (Л)
- working rotation of the shaft is left (only at the request of the customer)
- no number
- one separation section
- 2
- two separation sections are applied
- МН
- pump module
- ВГ
- vortex-type gas-separating stage
- Г
- gas-separating stage of the rotary type
- Д
- gas dispersing stage
- ГД
- gas separator/handler
- СГ
- gas stabilizer
- Р
- Raduzhny, manufactured by Almaz Oilfield Service
- no letter
- conventional design
- И
- wear-resistant design
- no letter
- conventional design
- К
- corrosion-resistant design (a combination of "IK" is allowed)
- Кн
- stainless steel housing
- Кп
- anticorrosive coating of the housing is applied
- 2А
- 69mm
- 3
- 81mm
- 4
- 86mm
- 4А
- 90mm
- 5
- 92mm
- 5.1
- 92mm, shaft 20mm
- 5А
- 103mm
- 5-5А
- size 5 with connecting sizes of size 5A
- 5А.1
- 103 mm, shaft 25 mm
- 6
- 114mm
- 6Б
- 130mm
ХХ – size:
- .Х
- shaft diameter code (may be not specified)
- no letter
- shaft material is stainless steel
- (М)
- shaft material is K-monel (or equivalent) – only at the request of the customer
- ХХХ
- upper limit of the flow rate operating range, m3/day
- no letter
- straight spline connection
- Э
- involute spline connection
- no letter
- basic design
- к
- to attach the ESP motor housing (manufactured by Almaz LLC)
- no letter
- conventional design (with a thrust runner)
- БО
- without a thrust runner (support in the protector)
- ОГ
- with a reinforced support of the thrust runner
- no letter
- basic design
- мв
- it is used in conjunction with the receiving module at the inlet to the pump module
- мг
- a base with an internal tubing thread (GOST 633-80) is used for mounting additional equipment
- no number
- six-point connection (serial)
- 8
- eight-point connection
- 10
- ten-point connection
due to the continuous improvement of products, the identification may differ slightly, at the same time the identification shall be adopted in accordance with the product passport. More detailed information can be clarified by contacting our specialists.
Description of identifiers
The structure of the pump module identifier in orders, correspondence and in other documentation:
- no letter
- working rotation of the shaft is right (serial)
- (Л)
- working rotation of the shaft is left (only at the request of the customer)
- no number
- one separation section
- 2
- two separation sections are applied
- МН
- pump module
- ВГ
- vortex-type gas-separating stage
- Г
- gas-separating stage of the rotary type
- Д
- gas dispersing stage
- ГД
- gas separator/handler
- СГ
- gas stabilizer
- Р
- Raduzhny, manufactured by Almaz Oilfield Service
- no letter
- conventional design
- И
- wear-resistant design
- no letter
- conventional design
- К
- corrosion-resistant design (a combination of "IK" is allowed)
- Кн
- stainless steel housing
- Кп
- anticorrosive coating of the housing is applied
- 2А
- 69mm
- 3
- 81mm
- 4
- 86mm
- 4А
- 90mm
- 5
- 92mm
- 5.1
- 92mm, shaft 20mm
- 5А
- 103mm
- 5-5А
- size 5 with connecting sizes of size 5A
- 5А.1
- 103 mm, shaft 25 mm
- 6
- 114mm
- 6Б
- 130mm
ХХ – size:
- .Х
- shaft diameter code (may be not specified)
- no letter
- shaft material is stainless steel
- (М)
- shaft material is K-monel (or equivalent) – only at the request of the customer
- ХХХ
- upper limit of the flow rate operating range, m3/day
- no letter
- straight spline connection
- Э
- involute spline connection
- no letter
- basic design
- к
- to attach the ESP motor housing (manufactured by Almaz LLC)
- no letter
- conventional design (with a thrust runner)
- БО
- without a thrust runner (support in the protector)
- ОГ
- with a reinforced support of the thrust runner
- no letter
- basic design
- мв
- it is used in conjunction with the receiving module at the inlet to the pump module
- мг
- a base with an internal tubing thread (GOST 633-80) is used for mounting additional equipment
- no number
- six-point connection (serial)
- 8
- eight-point connection
- 10
- ten-point connection
due to the continuous improvement of products, the identification may differ slightly, at the same time the identification shall be adopted in accordance with the product passport. More detailed information can be clarified by contacting our specialists.
Handler pump module
Name | size | ESP capacity, m³/day | Shaft diameter, mm | Weight, kg | Installation length, mm | Power consumption, kW, max | Transmitted power, kW | Maximum free gas content, %, min |
---|---|---|---|---|---|---|---|---|
МНДР(И)(К) 5.1-250 | 5.1 | 15-250 | 20 | 23 | 566 | 1 | до 120 | 0,55 |
МНДР(И)(К) 5.1-5А-250 | 5А | 25-250 | 20 | 24 | 566 | 1 | 120 | |
МНДР(И)(К) 5А-500 | 5А | 240-500 | 22 | 27 | 651 | 1 | 186 | |
МНДР(И)(К) 5А.1-500 | 5А.1 | 500-700 | 25 | 31 | 651 | 1 | 330 | |
МНДР(И)(К) 5А.1-800 | 5А.1 | 800 | 25 | 31 | 651 | 1 | 330 |